Technical Manual

EX7100 Technical Manual – Monitoring and Diagnostics
©1999 Exicom Technologies (1996) Ltd 4-3 Issue 2 - August 2001
1) From idle, press ‘Enter’.
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to PSU Monitoring and then press
‘Enter’.
3) Use the up and down arrows to position
the
next to the required parameter and
then press ‘Enter’ to view.
4) Press the ‘Escape’ key to back out of the
menu system.
4.2.3 Framer Parameters
> Bit Error Rate (BER)
EX7100 provides an indicator of BER performance. This should not be used as an
accurate measure of BER due to the lack of overhead bandwidth available. The system is
able to process, and thus indicate a BER of: <1x10
-6
(normal operation), 1x10
-5
,
1x10
-4
,
and 1x10
-3
.
1) From idle, press ‘Enter’.
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys to make
sure the
is next to Framer and then
press ‘Enter.
3) Use the up and down arrows until the
is
next to BER and then press ‘Enter’.
4) The value of BER is displayed. Press
‘Enter’ to change the BER Alarm trigger
point.
5) Press the ‘Escape’ key to back out of the
menu system.
4.3 Monitoring a Remote Terminal
From any terminal, it is possible to access the configuration, monitoring and diagnostics
system of any other terminal in the RF path.
Example (1) A two terminal link.
Figure 4.1: Two Terminal Link
framer
psu monitoring
+5 VDC rail
-5 VDC Rail
EX7100
Local Terminal
EX7100
Remote Terminal
Password 1
Password 1
RF parameters
framer
Tx Data Clock
ber
Ber: <1 x10E
-6
set alarm point
EX7100
EXICOM
o o
o o
o o
o
o
EX7100
EX7100
EXICOM
o o
o o
o o
o
o
EX7100