7. Refit the seven cap screws holding the heat sink casting into the main casting. (Refer
to Figure 7.15)
8. Inspect the EX7100 terminal to ensure that it is free of foreign material. Remove and
clean as required.
9. Replace the bottom cover, taking care to tighten every screw. No screws should be
left over at the end of the job.
10. Connect the antenna to the terminal. Apply power to the EX7100 rear panel and
switch the terminal on.
11. Return to normal operating mode and check that the link is correctly established. If
not refer to Testing & Fault Diagnosis (Section 7.5.2).
12. Re-install the EX7100 back into its rack and re-connect all necessary power,
signalling and antenna cabling.