User's Manual

EX7100 Technical Manual – VHF Fan Assembly
©2001 Exicom Technologies (1996) Ltd VHF Fan-2 Issue 0 – May 2001
Figure 1: Assembly connected to the EX7100 Terminal
4) Remove the Fan Box DC supply cable from the rear of the EX7100 Terminal, taking
careful note of the existing wire connections for future re-assembly (the BROWN wire is
connected to the +ve input and the BLUE wire is connected to the –ve input)
5) Carefully remove the Fan Box Assembly from the EX7100 Terminal. Access is now
available to the PA Heatsink casting.
6) Refer to Section 7 of the EX7100 Technical Manual for further information regarding the
replacement of the Heatsink casting and/or the PA Assembly.
7) Reverse the above-mentioned steps as required to re-assemble the Fan Box.