User's Manual

EX7100 Technical Manual - Module Descriptions
©1999 Exicom Technologies (1996) Ltd 7-71 Issue 3 - May 2001
2. Connect the negative probe of the DMM to pin 2 of connector PL3. Using the positive
probe of the DMM, touch pin 1 of PL3 and check the measured voltage against Table
7.6 below
Pin on
PL3
Expected Voltage Accepted
Tolerance
1 +5V ±0.25V
2 0V ±0.1V
Table 7.6: Typical Power Supply Measurement Ranges