Refer to Figure 7.27 and the steps outlined below:
Figure 7.27: UHF Duplex Filter Adjustment Locations
Note: From this point on the whole assembly will be referred to as the “Duplexer”, the
Band Reject Band Pass filter will be referred to as “BRBP”, the Band Pass Band Reject
filter as “BPBR” and the larger notch filter as “Duplex filter”.
The Duplexer is tuned in two steps. Initially the three parts (BRBP, BPBR and Duplex
filter) are tuned separately. The three parts are then connected together and the final
tuning is carried out to take into account the interaction between the three parts.
Bracketed ( ) numbers refer to the port numbers in figure 7.27 above.
Before undertaking the following procedures, ensure that the EX7100 terminal has been
powered down.
BRBP
Band Reject
Band Pass
Filter
(HPF)
BPBR
Band Pass
Band Reject
Filter
(LPF)
4 Cavity Duplex filter
Hig h
Low
low pass
adjustment
High pass
adjustment
Tx or Rx Tx or RxAntenna
1234567
A B C
D E F G
H I J