EX7100 Technical Manual – Monitoring and Diagnostics
©1999 Exicom Technologies (1996) Ltd 4-16 Issue 1 - February 2001
4) Use the up and down arrow keys to make
sure the → is next to the required
interface type. An ∗ indicates the current
interface.
Press ‘Enter’ to accept.
5) Press ‘Escape’ once to return to the
previous menu.
D) Set the EX7100 terminals so that the Transmitted data is clocked from the received
data stream, as follows:
1) Use the up and down arrow keys to make
sure the → is next to Tx Data Clock.
Press ‘Enter.’
2) Use the up and down arrows to select the
digital interface being used.
Press ‘Enter.’
3) Select the synchronisation source
required.
Press ‘Enter.’
4) Press ‘Escape’ until the main menu is
displayed.
E) Set both EX7100 terminals to 100% operation as follows:
1) Use the up and down arrow keys to make
sure the →
→→
→ is next to Controller.
Press ‘Enter.’
2) The screen will read Operating Mode.
Press ‘Enter’
3) Use the up and down arrow keys to
choose Terminal 100%, and press ‘Enter’
4) Press ‘Escape’ until the display returns to
idle.
F) The BER test may now begin. When complete, return each terminal to its original
configuration.
→G.703 codir
G.703 contra
Interface
→Tx Data Clock
→G.703
Sync data
int ref
→Sync to rx
→operating mode
set Time / date
→controller
rf parameters
→terminal 100%
term on demand