User's Manual

EX7100 Technical Manual – Monitoring and Diagnostics
©1999 Exicom Technologies (1996) Ltd 4-9 Issue 1 - February 2001
1) Press ‘Enter’. You will be given a list of all
alarms available within the terminal
2) Use the up and down arrow keys to select
the alarm you wish to set and then press
‘Enter’ to select.
3) The asterisk (*) indicates which priority is
set for that alarm. Use the left and right
arrow keys to change the priority and then
press ‘Enter’ to accept the change.
4) Continue to check/set the priorities for
each alarm and then press ‘Escape’ until
the display returns to idle.
4.4.3 Link Up Time Alarm
The EX7100 provides an alarm to indicate when the link has been up longer than the set
time limit. This may be useful in the case where a site is battery/solar powered and it is
necessary to know if the link is being held up for any reason.
The Link Up Time Alarm may be set for the following times:
Off, 1 Hour, 3 Hours, 6 Hours, 9 Hours, 12 Hours, 18 Hours, 24 Hours.
To set the Link Up Time Alarm:
1) From idle, press ‘Enter’
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys to make
sure the
is next to Alarms and then
press ‘Enter’
3) Use the up and down arrow keys to make
sure the
is next to Link Up Time and
then press ‘Enter’.
4) Use the up and down arrow keys to
choose the required alarm time and then
press ‘Enter’ to accept.
Note that the currently selected option is
indicated by an asterisk.
5) Press ‘Escape’ until the display returns to
idle
Alarm Log
Priorities
Low RSSI
Tx Power drop
Tx power drop
* low High
Remote tests
Alarms
Priorities
Link up time
Off
1 hour
Password 1