User's Manual

EX7100 Technical Manual – Monitoring and Diagnostics
©1999 Exicom Technologies (1996) Ltd 4-2 Issue 1 - February 2001
1) From idle, press ‘Enter’.
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to RF Parameters and then press
‘Enter’.
3) Use the up and down arrows to position
the
next to the required parameter and
then press ‘Enter’ to view.
4) Press the ‘Escape’ key to back out of the
menu system. Pressing ‘Escape’ three
times will return the display to idle.
4.2.2 Power Supply Parameters
The power supply provides the monitoring system with the status of all voltage rails, as
well as DC input voltage and Input current drawn.
> +5 VDC Rail
> -5 VDC Rail
> +15 VDC Rail
> -15 VDC Rail
> +24 VDC Rail
> DC Input Voltage
> Input Current
> Charge Current.
1
1) From idle, press ‘Enter’.
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrows until the
is
next to PSU Monitoring and then press
‘Enter’.
3) Use the up and down arrows to position
the
next to the required parameter and
then press ‘Enter’ to view.
4) Press the ‘Escape’ key to back out of the
menu system.
1
Requires an external shunt to operate. The shunt is not supplied as standard, it will need to be purchased separately.
rf parameters
framer
RSSI
tx power
framer
psu monitoring
+5 VDC rail
-5 VDC Rail
Password 1
Password 1