User's Manual

EX7100 Technical Manual - Configuring the Terminal
©1999 Exicom Technologies (1996) Ltd 3-6 Issue 1 - May 2001
4) Use the up and down arrow keys to
choose the required operating mode and
then press ‘Enter’.
Note that the current setting is indicated by
an asterisk.
5) Press ‘‘Escape’’ until the display returns to
idle.
Link ID.
The Link ID is the identification number for the link. There are 99 possible numbers from
1-99. (The factory default setting is 01)
Both terminals in the link must have the same Link ID setting. (If a repeater configuration
is used, see Section 8, all
terminals must have the same link ID).
1) From idle, press ‘Enter’
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys to make
sure the
is next to Controller and then
press ‘Enter’.
3) Use the up and down arrow keys until the
is next to Change Link ID and then
press ‘Enter’.
4) Use the arrow keys to enter the required
link identification number (0-99)
Note: all terminals in a link must
have the
same Link ID (including repeaters).
Press ‘Enter’ to accept changes.
5) Press ‘Escape’ until the display returns to
idle.
Terminal Descriptor.
If required, a 16-character description of the terminal can be set. If changed from the
factory default setting, the terminal descriptor will be displayed on the front panel while the
user interface is idle, and will be displayed instead of the ESN when being accessed from
a remote location.
1) From idle, press ‘Enter’
Use the arrow keys to enter the First Level
password ‘1111’ and then press ‘Enter’.
2) Use the up and down arrow keys to make
sure the
is next to Controller.
Press ‘Enter’.
Change password
change Link id
Password 1
Controller
rf parameters
Link id: 01
Password 1
Controller
rf parameters
terminal 100%
term on demand