3) The local terminal’s transmitter will turn
off (Tx LED will go off), allowing the user
to adjust the antenna safely. The remote
Tx will remain on for up to 60 minutes.
RSSI is now displayed on the screen as
well as on the voltmeter inputs on the
front panel.
4) While one person watches the RSSI
level, the other should move the antenna
direction slightly until the RSSI level is at
its highest. This is the optimum antenna
alignment. Make sure you stand at least
one metre behind the active element
while taking a reading so as not to cause
interference. Tighten the mounting bolts.
(Note: One person can do both tasks if a
voltmeter with long leads is connected to
the jacks on the front panel.
5) Press ‘Escape’. The link will restart and
the menu will return to Antenna Align.
Press ‘Escape’ again then use the up
and down arrows to make sure the →
→→
→ is
next to End Remote Tests and then
press ‘Enter’.
This completes the installation of the terminal.
Repeat this “Final Antenna Alignment” procedure for the other terminal.