User's Manual

EX7100 Technical Manual - Module Descriptions
©1999 Exicom Technologies (1996) Ltd 7-70 Issue 3 - May 2001
Accessing the Isolated Power Supply Module
Remove the top cover as per Section 6.1.
Diagnosis
1. Connect the negative probe of the digital multi-meter (DMM) to pin 1 of connector
PL2. Using the positive probe of the DMM, touch all the other pins of PL2 in turn and
check the measured voltage against Table 7.5 below:
Pin on
PL2
Expected Voltage Accepted
Tolerance
1 0V ±0.1V
2 +5V ±0.25V
3 -48V ±4.0V
4 +5V ±0.25V
5 0V ±0.1V
6 -5V ±0.5V
7 -5V ±0.5V
8 0V ±0.1V
9 +5V ±0.25V
10 +100V ±10.0V
Table 7.5: Typical Power Supply Measurement Ranges