User's Manual
Table Of Contents
EX7100 Technical Manual - Module Descriptions
©1999 Exicom Technologies (1996) Ltd 7-50 Issue 3 - May 2001
7.9.4 VHF Duplex Filter Replacement Procedure
Note: Ensure that the replacement module has been correctly tuned to the operating
frequencies required before installation (refer to Section 7.9.3 above)
1. Isolate the EX7100 Terminal from the incoming DC supply by removing the DC input
wires from the rear panel terminal block.
2. Remove the top cover as described in Section 6.1.
3. Note the connector positions and the way that the cables are run (it is important that
all cables are replaced as they were initially run before the module replacement
procedure). Disconnect the three coax cables from the Duplexer.
4. Remove the fasteners holding the Duplexer to the cover and lift it clear.
5. Fit the new Duplexer over the threaded studs and replace the fasteners. Tighten the
fasteners.
6. Reconnect the three coaxes to the positions recorded previously.
7. Inspect the EX7100 terminal to ensure that it is free of foreign material. Remove and
clean as required.
8. Connect the antenna to the terminal. Apply power to the EX7100 rear panel and
switch the terminal on.
9. Check that the received signal strength (RSSI) and forward power are at the levels
expected and that the VSWR alarm is not being generated.