User's Manual

EX7100 Technical Manual - Module Descriptions
©1999 Exicom Technologies (1996) Ltd 7-41 Issue 3 - May 2001
The module contains semi-conductor components that are
sensitive to electrostatic damage.
Electrostatic sensitive devices should only be stored and
transported inside electrically conductive static shielding
bags. Fault finding and module replacement must be
performed at “electrostatically safe work stations” where the
work bench surface, soldering iron and the operator are all
earthed to prevent the build up of harmful electrostatic
charges.
Accessing the UHF Receiver Module
To gain service access to the Receiver module, remove the bottom cover as per Section
6.1.
Diagnosis
With the unit de-powered, check the receiver module visually for signs of damage such
as burnt tracks or components. Check that all connectors are fully mated. If no damage
is apparent, apply power and follow the steps outlined in Figure 7.24 overleaf