Owner's manual
Copper Tests: Using the Main Menu
Copper Test 67
Application Settings
 Capacitance Measurement is either 3 Terminal or 2 Terminal. The 
latter method measures the capacitance across the 2 terminals 
specified (either T-R, T-G, R-G or A-B, A-E, B-E), whereas the 3 Terminal 
method measures the capacitance across the 2 terminals specified, 
and shorts the remaining (or unspecified) terminal to G/E.
Note: In order to correctly determine cable length by using the capacitance 
measurement, the Cable Book must contain both 3/2 Terminal values.
 Test Startup Mode lists the test startup type:
 Auto (default) automatically starts a test when you select the 
respective icon from the test sub-menu.
 Manual requires that you tap the Start button on the Main Menu to 
start a test.
 Result File Storage Location allows you to select where to save your 
results: to a USB or the internal memory.
 Report Format is HTML, MHTML, XML, or PDF as the generated report 
format.
 Prompt To Save Results allows you to enable popup confirmation 
messages before leaving a test and not saving results, by checking the 
box.
 Show Connection Diagram On Test Startup allows you to enable the 
hookup diagram upon startup by checking the boxes of the following 
tests:
 Xtalk
 Station Ground
 NEXT