User Guide FTB-2200 Broadband Source for FTB-200 v2
Copyright © 2011–2014 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form, be it electronically, mechanically, or by any other means such as photocopying, recording or otherwise, without the prior written permission of EXFO Inc. (EXFO). Information provided by EXFO is believed to be accurate and reliable.
Contents Certification Information ....................................................................................................... iv 1 Introducing the FTB-2200 Broadband Source ............................................ 1 Typical Applications ................................................................................................................1 Conventions ............................................................................................................................
Certification Information Certification Information North America Regulatory Statement This unit was certified by an agency approved in both Canada and the United States of America. It has been evaluated according to applicable North American approved standards for product safety for use in Canada and the United States. Electronic test and measurement equipment is exempt from FCC part 15, subpart B compliance in the United States of America and from ICES-003 compliance in Canada. However, EXFO Inc.
1 Introducing the FTB-2200 Broadband Source The FTB-2200 Broadband Source is a polarization scrambled broadband LED source covering the C + L bands. It is ideal for high-accuracy polarization mode dispersion (PMD) measurement and has been specifically designed to be used with EXFO’s FTB-5500B PMD Analyzer.
Introducing the FTB-2200 Broadband Source Conventions Conventions Before using the product described in this guide, you should understand the following conventions: WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Do not proceed unless you understand and meet the required conditions. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
2 Safety Information WARNING Do not install or terminate fibers while a light source is active. Never look directly into a live fiber and ensure that your eyes are protected at all times. WARNING The use of controls, adjustments and procedures, namely for operation and maintenance, other than those specified herein may result in hazardous radiation exposure or impair the protection provided by this unit.
Safety Information Your instrument is a Class 1M laser product in compliance with standards IEC 60825-1: 2007 and 21 CFR 1040.10, except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. Invisible laser radiation may be encountered at the output port. WARNING Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard.
3 Setting Up and Operating the Broadband Source Inserting and Removing Test Modules CAUTION Never insert or remove a module while the FTB-200 v2 Compact Modular Platform is turned on. This will result in immediate and irreparable damage to both the module and unit. CAUTION To avoid damaging your unit, use it only with modules approved by EXFO. WARNING When the laser safety LED is flashing, at least one of your modules is emitting an optical signal.
Setting Up and Operating the Broadband Source Inserting and Removing Test Modules To insert a module into the FTB-200 v2 Compact Modular Platform: 1. Turn off your unit. 2. Position the unit so that its front panel is facing you.
Setting Up and Operating the Broadband Source Inserting and Removing Test Modules 3. Take the module and place it vertically so that the retaining screw hole is at the left of the connector pins. CAUTION Inserting a module upside down could result in permanent damage to the module, as the connector pins might be bent. 4. Insert the protruding edges of the module into the grooves of the unit’s module slot. 5.
Setting Up and Operating the Broadband Source Inserting and Removing Test Modules 7. While applying slight pressure to the module, lift the mobile part of the retaining screw and use it to turn the retaining screw clockwise until it is tightened. This will secure the module into its “seated” position. Turn retaining screws clockwise Bottom panel When you turn on the unit, the startup sequence will automatically detect the module.
Setting Up and Operating the Broadband Source Inserting and Removing Test Modules To remove a module from the FTB-200 v2 Compact Modular Platform: 1. Turn off your unit. 2. Position the unit so that the bottom panel is facing you. 3. Lift the mobile part of the retaining screw and use it to turn the retaining screw counterclockwise until it stops. The module will be slowly released from the slot. Turn retaining screws counterclockwise Bottom panel 4. Place the unit so that the top panel is facing you.
Setting Up and Operating the Broadband Source Inserting and Removing Test Modules 5. Hold the module by its sides or by the handle (NOT by the connector) and pull it out. CAUTION Pulling out a module by a connector could seriously damage both the module and connector. Always pull out a module by its casing. 6. Cover empty slots with the supplied protective covers.
Setting Up and Operating the Broadband Source Starting Module Applications Starting Module Applications Your modules can be configured and controlled from their dedicated applications in Compact ToolBox. To start a module application: 1. From Compact ToolBox, select the module to use. It will turn blue to indicate that it is highlighted. 2. Under Applications, select an application, then press Start. To start the Power Meter or Probe application: From Main Menu, press Power Meter or Probe.
Setting Up and Operating the Broadband Source Starting Module Applications The main window (shown below) contains all the commands required to control the Broadband Source: Display pane Function Tabs Control Center 12 FTB-2200
Setting Up and Operating the Broadband Source Cleaning and Connecting Optical Fibers Cleaning and Connecting Optical Fibers IMPORTANT To ensure maximum power and to avoid erroneous readings: Always inspect fiber ends and make sure that they are clean as explained below before inserting them into the port. EXFO is not responsible for damage or errors caused by bad fiber cleaning or handling. Ensure that your patchcord has appropriate connectors.
Setting Up and Operating the Broadband Source Cleaning and Connecting Optical Fibers 3. Carefully align the connector and port to prevent the fiber end from touching the outside of the port or rubbing against other surfaces. If your connector features a key, ensure that it is fully fitted into the port’s corresponding notch. 4. Push the connector in so that the fiber-optic cable is firmly in place, thus ensuring adequate contact.
Setting Up and Operating the Broadband Source Installing the EXFO Universal Interface (EUI) Installing the EXFO Universal Interface (EUI) The EUI fixed baseplate is available for connectors with angled (APC) or non-angled (UPC) polishing. A green border around the baseplate indicates that it is for APC-type connectors. Green border indicates APC option Bare metal (or blue border) indicates UPC option To install an EUI connector adapter onto the EUI baseplate: 1.
Setting Up and Operating the Broadband Source Activating or Deactivating Light Emission Activating or Deactivating Light Emission Before activating the source, read the Safety Information on page 3. Note: You should let the source warm up for 30 minutes to obtain optimum wavelength stability. To activate or deactivate light emission: 16 Select ON to activate the light emission. The ACTIVE LED on the module’s front panel lights up, indicating that the source is active.
4 Maintenance To help ensure long, trouble-free operation: Always inspect fiber-optic connectors before using them and clean them if necessary. Keep the unit free of dust. Clean the unit casing and front panel with a cloth slightly dampened with water. Store unit at room temperature in a clean and dry area. Keep the unit out of direct sunlight. Avoid high humidity or significant temperature fluctuations. Avoid unnecessary shocks and vibrations.
Maintenance Cleaning Fixed Connectors Cleaning Fixed Connectors Regular cleaning of connectors will help maintain optimum performance. Do not try to disassemble the unit. Doing so would break the connector. WARNING Looking into the optical connector while the light source is active WILL result in permanent eye damage. EXFO strongly recommends to TURN OFF the unit before proceeding with the cleaning procedure. To clean fixed connectors: 1. Fold a lint-free wiping cloth in four to form a square. 2.
Maintenance Cleaning Fixed Connectors 5. Throw out the wiping cloths after one use. 6. Moisten a cleaning tip (2.5 mm tip) with only one drop of isopropyl alcohol. IMPORTANT Alcohol may leave traces if used abundantly. Avoid contact between the tip of the bottle and the cleaning tip, and do not use bottles that distribute too much alcohol at a time. 7. Slowly insert the cleaning tip into the connector until it reaches the ferrule inside (a slow clockwise rotating movement may help). 8 7 9 8.
Maintenance Cleaning EUI Connectors Cleaning EUI Connectors Regular cleaning of EUI connectors will help maintain optimum performance. There is no need to disassemble the unit. IMPORTANT If any damage occurs to internal connectors, the module casing will have to be opened and a new calibration will be required. WARNING Looking into the optical connector while the light source is active WILL result in permanent eye damage.
Maintenance Cleaning EUI Connectors 3 4 5 4. Gently turn the cleaning tip one full turn, then continue to turn as you withdraw it. 5. Repeat steps 3 to 4 with a dry cleaning tip. Note: Make sure you don’t touch the soft end of the cleaning tip. 6. Clean the ferrule in the connector port as follows: 6a. Deposit one drop of isopropyl alcohol on a lint-free wiping cloth. IMPORTANT Isopropyl alcohol may leave residues if used abundantly or left to evaporate (about 10 seconds).
Maintenance Recalibrating the Unit Recalibrating the Unit EXFO manufacturing and service center calibrations are based on the ISO/IEC 17025 standard (General Requirements for the Competence of Testing and Calibration Laboratories). This standard states that calibration documents must not contain a calibration interval and that the user is responsible for determining the re-calibration date according to the actual use of the instrument. The validity of specifications depends on operating conditions.
Maintenance Recycling and Disposal (Applies to European Union Only) To help you with calibration follow-up, EXFO provides a special calibration label that complies with the ISO/IEC 17025 standard and indicates the unit calibration date and provides space to indicate the due date.
5 Troubleshooting Solving Common Problems Problem Source appears unstable. Possible Cause Insufficient Wait a minimum Reflection Connect the Ambient Control ambient stabilization time. destabilizing the source. temperature is varying. Broadband Source Solution of 30 minutes for optimum stabilization. source using an optical isolator. temperature.
Troubleshooting Obtaining Online Help Obtaining Online Help An online version of the FTB-2200 Broadband Source user guide is conveniently available at all times from the application. Note: You will also find a printable PDF version on your installation DVD. To access online help: Click the Help button on the function bar.
Troubleshooting Contacting the Technical Support Group Contacting the Technical Support Group To obtain after-sales service or technical support for this product, contact EXFO at one of the following numbers. The Technical Support Group is available to take your calls from Monday to Friday, 8:00 a.m. to 7:00 p.m. (Eastern Time in North America). Technical Support Group 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADA 1 866 683-0155 (USA and Canada) Tel.: 1 418 683-5498 Fax: 1 418 683-9224 support@exfo.
Troubleshooting Transportation You may also be requested to provide software and module version numbers. This information, as well as technical support contact information, can be found in the About function tab. Select the Technical Support tab to view phone numbers and active Internet links to EXFO’s Technical Support Group. Use these links to send an information request by e-mail or to access EXFO’s web site.
6 Warranty General Information EXFO Inc. (EXFO) warrants this equipment against defects in material and workmanship for a period of one year from the date of original shipment. EXFO also warrants that this equipment will meet applicable specifications under normal use.
Warranty Liability Liability EXFO shall not be liable for damages resulting from the use of the product, nor shall be responsible for any failure in the performance of other items to which the product is connected or the operation of any system of which the product may be a part. EXFO shall not be liable for damages resulting from improper usage or unauthorized modification of the product, its accompanying accessories and software.
Warranty Service and Repairs Service and Repairs EXFO commits to providing product service and repair for five years following the date of purchase. To send any equipment for service or repair: 1. Call one of EXFO’s authorized service centers (see EXFO Service Centers Worldwide on page 32). Support personnel will determine if the equipment requires service, repair, or calibration. 2.
Warranty EXFO Service Centers Worldwide EXFO Service Centers Worldwide If your product requires servicing, contact your nearest authorized service center. EXFO Headquarters Service Center 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADA EXFO Europe Service Center Winchester House, School Lane Chandlers Ford, Hampshire S053 4DG ENGLAND EXFO Telecom Equipment (Shenzhen) Ltd. 3rd Floor, Building 10, Yu Sheng Industrial Park (Gu Shu Crossing), No.
Index Index A About function tab ..................................... 28 activating source ......................................... 16 after-sales service ........................................ 27 application contacting EXFO support from .............. 28 application, starting .................................... 11 F fiber ends, cleaning ..................................... 13 firmware version, module............................ 28 front panel, cleaning ...................................
Index P W PDF. see online user guide product identification label................................. 27 warranty certification............................................ 30 exclusions .............................................. 30 general................................................... 29 liability ................................................... 30 null and void.......................................... 29 R removing a module .......................................
NOTICE 抩⛙ CHINESE REGULATION ON RESTRICTION OF HAZARDOUS SUBSTANCES ₼⦌␂ℝ☀⹂䓸德棟Ⓟ䤓屓⸩ NAMES AND CONTENTS OF THE TOXIC OR HAZARDOUS SUBSTANCES OR ELEMENTS CONTAINED IN THIS EXFO PRODUCT ▔⚺⦷㦻 EXFO ℶ❐₼䤓㦘㹡㦘⹂䓸德㒥⏒侯䤓⚜䱿✛⚺摞 O X Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006 嫷䯉年㦘㹡㦘⹂䓸德⦷年捷ↅ㓏㦘⧖德㧟㠨₼䤓⚺摞⧖⦷ SJ/T11363-2006 㪖屓⸩䤓 棟摞尐㻑ⅴₚᇭ Indicates that this toxic or hazardous substance contained in at least one of the
MARKING REQUIREMENTS 㪖㽷尐㻑 Product Environmental protection use period (years) Logo ℶ❐ 䘾⬒≬㔳∎䞷㦮棟 ( ) 㪖㉦ This Exfo product 㦻 EXFO ℶ❐ Batterya 䟄㻯 a a. If applicable.
P/N: 1064485 www.EXFO.com · info@exfo.com CORPORATE HEADQUARTERS 400 Godin Avenue Quebec (Quebec) G1M 2K2 CANADA Tel.: 1 418 683-0211 · Fax: 1 418 683-2170 EXFO AMERICA 3400 Waterview Parkway Suite 100 Richardson, TX 75080 USA Tel.: 1 972-761-927 · Fax: 1 972-761-9067 EXFO EUROPE Winchester House, School Lane Chandlers Ford, Hampshire S053 4DG ENGLAND Tel.: +44 2380 246 800 · Fax: +44 2380 246 801 EXFO ASIA-PACIFIC 100 Beach Road, #25-01/03 Shaw Tower SINGAPORE 189702 Tel.