User Manual
FTB-720C—LAN/WAN Access OTDR
EXFO is certified ISO 9001 and attests to the quality of these products. EXFO has made every effort to ensure that the information contained in this specification sheet is accurate. However, we accept no
responsibility for any errors or omissions, and we reserve the right to modify design, characteristics and products at any time without obligation. Units of measurement in this document conform to SI standards and
practices. In addition, all of EXFO’s manufactured products are compliant with the European Union’s WEEE directive. For more information, please visit www.EXFO.com/recycle. Contact EXFO for prices and
availability or to obtain the phone number of your local EXFO distributor.
For the most recent version of this spec sheet, please go to the EXFO website at www.EXFO.com/specs.
In case of discrepancy, the web version takes precedence over any printed literature.
EXFO Headquarters
>
Tel.: +1 418 683-0211
|
Toll-free: +1 800 663-3936 (USA and Canada)
|
Fax: +1 418 683-2170
|
info@EXFO.com
|
www.EXFO.com
EXFO serves over 2000 customers in more than 100 countries. To find your local office contact details, please go to www.EXFO.com/contact.
SPFTB720C.5AN © 2019 EXFO Inc. All rights reserved. Printed in Canada 19/01
ORDERING INFORMATION
FTB-720C-XX-XX-XX-XX
Model
FTB-720C = OTDR
Optical configuration
SM1 = SM OTDR, 1310/1550 nm
SM2 = SM OTDR, 1310/1550 nm and 1625 nm live
a
Q1 = MM OTDR, 850/1300 nm. QUAD-ready
a
Q1-QUAD = QUAD OTDR, 850/1300 nm
and 1310/1550 nm
Base software
OTDR = Enables OTDR application only
iOLM = Enables iOLM application only
Oi = Enables OTDR and iOLM applications
iOLM software option
b
00 = iOLM Standard
iADV = iOLM Advanced
iLOOP = iOLM loopback mode
iCERT = iOLM tier-2 certification
Singlemode and multimode connector
c
EA-EUI-28 = APC/DIN 47256
EA-EUI-89 = APC/FC narrow key
EA-EUI-91 = APC/SC
EA-EUI-95 = APC/E-2000
EA-EUI-98 = APC/LC
EI-EUI-28 = UPC/DIN 47256
EI-EUI-89 = UPC/FC narrow key
EI-EUI-90 = UPC/ST
EI-EUI-91 = UPC/SC
EI-EUI-95 = UPC/E-2000
EI-EUI-98 = UPC/LC
EI connectors = See section below about APC connectors
Example: FTB-720C-SM1-OTDR-EA-EUI-89
Notes
a. The two ports are configured with the same adapter.
b. Please refer to the iOLM specification sheet for the complete and most recent description of these value packs.
c. Multimode connectors available in EI (UPC) only.
EI CONNECTORS
To maximize the performance of your OTDR, EXFO recommends using APC connectors on singlemode port. These connectors generate lower
reflectance, which is a critical parameter that affects performance, particularly in dead zones. APC connectors provide better performance than UPC
connectors, thereby improving testing efficiency.
For best results, APC connectors are mandatory with the iOLM application.
Note: UPC connectors are also available. Simply replace EA-XX by EI-XX in the ordering part number. Additional connector available: EI-EUI-90 (UPC/ST).
GENERAL SPECIFICATIONS
Size (H x W x D) 50 mm x 254 mm x 210 mm (2 in x 10 in x 8 ¼ in)
Weight 0.4 kg (0.8 lb)
Temperature Operating
Storage
Refer to platform’s specification sheet
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity 0% to 95% non-condensing
This picture is shown as a guideline only. Actual module
may differ depending on the configuration selected.
LASER SAFETY
INVISIBLE LASER RADIATION
VIEWING THE LASER OUTPUT WITH
CERTAIN OPTICAL INSTRUMENTS (FOR
EXAMPLE, EYE LOUPES, MAGNIFIERS
AND MICROSCOPES) WITHIN A DISTANCE
OF 100 MM MAY POSE AN EYE HAZARD
CLASS 1M LASER PRODUCT