User Manual
CableSHARK P3 User Guide 
227
SEND TONE
600 OHMS
GRAPHICAL
300 Hz to 4 kHz
EDIT /
SELECT
MAIN
MENU
Test Typ e :
Term Impedance:
Receiver Mode:
Graph Scale:
EF
CHG
RECEIVE TONE
F
IGURE 15.2.2A - SETTING UP RX TONE GRAPHICAL TEST 
The VF TEST menu has the following configuration option. 
TEST TYPE: 
Select RECEIVE TONE 
TERM IMP: 
600 ohms (or 100, 150 ohms if your unit does not have 600 ohms installed). 
Receiver Mode: 
Allows user to select from NUMERICAL, GRAPHICAL, and RX 3 TONE SLOPE. 
Graph Scale: 
Allows user to select from 300 Hz to 4 kHz or 300 Hz to 20 kHz. 
With GRAPHICAL selected, press the RUN/STOP key to start the test. The following screen will appear. 