User Manual
VF / DSL Cable Qualifier 
218 
The VF TEST menu has the following configuration option. 
TEST TYPE: 
Select SEND TONE 
TERM IMP: 
600 ohms (or 100, 150 ohms if your unit does not have 600 ohms installed). 
Level (dBm): 
Level can be set from –16 dBm to +18 dBm. Use the asterisk key ( * ) to toggle 
between minus ( - ) and plus ( + ) symbols. 
Frequency Mode: 
Allows user to select from SPOT, VARIABLE, TX 3 TONE SLOPE and TRACING 
TONE. 
With SPOT frequency selected, press the RUN/STOP key to start the test. The following screen is displayed. 
FIGURE 15.1.2B - RUNNING THE SPOT TEST 
The SPOT frequency screen allows a user to modify what is being transmitted from the CableSHARK. 
Simply scroll up and down the column titled FREQUENCY and the CableSHARK that frequency and the 