User Manual
VF / DSL Cable Qualifier 
202 
For temperatures in Celsius: 
R
TC
 = R
20°C
 + T
C
 - 20°C ) * 0.00393 * R
20°C
] 
 Where R
TC
 = new resistance based on new temperature in Celsius 
            T
C
 = new temperature 
   R
20°C
 = resistance of the cable @ 20°C 
11. The RFL measurement is designed to find a single fault. If multiple faults exist, an incorrect 
measurement will be given. If the result does not coincide with a splice point or equipment location, 
then the test will have to re-done and the loop under test sectionalized to narrow down the location 
of the impairment. 
T
R
T
R