 Table 12.3.1 
 Loop Resistance @ 68°F or 20°C 
Wire Gauge  Resistance 
mm AWG 
Ω/km  Ω/kft  Ω/mi 
0.32 PE 28 409 125 658 
0.40 PE    280  84.4  451 
 26 PIC 273  83.1 439 
0.50 PE    179  54.5  288 
 24 PIC 172  52.3 276 
0.60 PE    123  37.5  198 
0.63 PE    113  34.5  182 
 22 PIC 108  32.9 174 
0.80 PE    69  21.0  111 
0.90 PE    55  16.8  88.5 
 19 PIC 53.8 16.4 86.6 
NOTES: 
  PE = metric Polyethylene insulated cable 
  PIC = AWG Polyethylene insulated cable 
Metric & AWG Wire Gauges: R & C (0Hz/DC, 20°C or 68°F)
10.  For a resistance at a temperature other than 68°F or 20°C, use the following formula. Note that 
these calculations are for copper cabling only. 
For temperatures in Fahrenheit: 
R
TF
 = R
68°F
 + [ 0.0022 * ( T
F
 - 68°F ) * R
68°F 
] 
 Where R
TF
 = new resistance based on new temperature in Fahrenheit 
            T
F
 = new temperature 
 R
68°F
 = resistance of the cable @ 68°F 