User Manual
VF / DSL Cable Qualifier 
170 
MAIN
MENU
EF
CHG
VIEW
DETAIL
SAVE /
UPLOAD
DMM:
Load Coil
Length 
Longitudinal Balance
Balance at 1 Khz
Capacitive Imbalance
SHDSL Data Rate
Disturbed ID
      Passed
3 found    Failed
2999 f t 
      Skipped
N/A
      Skipped
      Undetermined
Failed
Cable length: 2999 ft. dBRL = 40.5+ Load coil or splitter detected
FIGURE 8.11.4B - RESULTS OF THE SHDSL AUTO TEST - FAIL 
The functions buttons at the bottom of the screen are as follows: 
VIEW DETAIL 
Allows a user to view the results of each test making up a completed SHDSL Auto 
test. The SHDSL Auto test will not do a Single-End SHDSL test if a Load Coil is 
detected. 
Pressing the SAVE / UPLOAD button shows a pop-up window where the user is allowed to upload results, 
and save results to internal memory or to external USB memory. 
UPLOAD 
RESULT 
Choosing UPLOAD RESULT from the SAVE / UPLOAD pop-up menu sends the result 
that appears on the CableSHARK screen (current test or recalled test) to a PC via a 
NULL modem cable. The remote control program Visi-SHARK can be used to capture 
and analyze the results on a PC. 
SAVE TO MEM 
Choosing SAVE TO MEM from the SAVE / UPLOAD pop-up menu invokes the SAVE 
SESSION menu. From here, the test results can be saved to internal non-volatile 
memory. See Section 5.3 for more information. 
SAVE TO USB 
Choosing SAVE TO USB from the SAVE / UPLOAD pop-up menu invokes the SAVE 
SESSION menu. From here, the test results can be saved to external USB memory. 
See Section 5.3 for more information. 