User Manual
CableSHARK P3 User Guide 
167
MAIN
MENU
EF
CHG
VIEW
DETAIL
SAVE /
UPLOAD
DMM:
Load Coil:
Length (TDR):
Balance at 1 kHz 
Dialing: 4165551212
   (DATU)
Loss
Frequency
C-Msg Noise
PI C-Msg.
none found  
N/A  
N/A
6.6 dB
1.004 kHz
-24.2 dBrnC
51.8 dBrnC
Passed
Passed
Passed  
POTS Test Complete
Passed
Passed
Passed
FIGURE 8.11.3A - RESULTS OF THE VF AUTO TEST - PASS 
At the conclusion of the VF AUTO POTS (or NO POTS) test, the CableSHARK will report PASSED if all the 
user defined thresholds are not compromised. Otherwise, the CableSHARK will report FAILED. 
The functions buttons at the bottom of the screen are as follows: 
VIEW DETAIL 
Allows a user to view the results of each test making up a completed VF Auto test. 
Pressing the SAVE / UPLOAD button shows a pop-up window where the user is allowed to upload results, 
and save results to internal memory or to external USB memory. 
UPLOAD 
RESULT 
Choosing UPLOAD RESULT from the SAVE / UPLOAD pop-up menu sends the result 
that appears on the CableSHARK screen (current test or recalled test) to a PC via a 
NULL modem cable. The remote control program Visi-SHARK can be used to capture 
and analyze the results on a PC. 
SAVE TO MEM 
Choosing SAVE TO MEM from the SAVE / UPLOAD pop-up menu invokes the 
SAVE SESSION menu. From here, the test results can be saved to internal 
non-volatile memory. See Section 5.3 for more information. 