8.11.1.2  SHDSL Auto Test Setup 
From the Auto Test Setup screen, pressing the F6 button will activate the SHDSL Auto Test Setup screen. 
The SHDSL Auto Test setup screen allows you to configure the PASS/FAIL criteria for the SHDSL Auto 
Test. 
MAIN
MENU
EF
CHG
VF
SETUP
EDIT/
SELECT
DEFAULT
VALUES
SHDSL Evaluation:
SHDSL Noise Margin dB:
Min. SHDSL Rate (kbps):
VOP:
Capacitance nF/mi T-R:
Capacitance nF/mi to GND:
Max. AC Voltage T-R (V):
Min. Res. T-R (Mohm):
Max. AC Voltage T-G (V): 
Max. AC Voltage R-G (V):
Max. DC Voltage T-R (V):
Max.DC Voltage to GND(V):
Min. Res. T-G (Mohm):
Min. Res. R-G (Mohm):
Max. Cap. Imbalance (%):
Min. VF Long.Balance (dB):
0
AUTO
500.0
0.660
83.0
125.0
10.0
25.0
25.0
50.0
50.0
2.5
2.5
2.5
5.0
50.0
ITU-T Annex A
SELECT
NEXT
ADSL
SETUP
FIGURE 8.11.1.2A – SHDSL AUTO TEST SETUP 
The options at the bottom of the SHDSL AUTO TESTS SETUP screen represent the following: 
EDIT/SELECT 
Pressing the function button corresponding to EDIT/SELECT invokes a menu 
wherein a desired parameter can be highlighted by using the Cursor Pad 
UP/DOWN arrow buttons and/or the function buttons corresponding to PAGE 
UP and PAGE DOWN (should they exist). Press the function button 
corresponding ENTER to select the highlighted parameter. 
SELECT PREVIOUS 
Pressing the function button corresponding to SELECT PREVIOUS scrolls 
backward through each of the parameters that are available for the highlighted 
option. 