Specifications

XP250 INSTALLATION AND OPERATION MANUAL
Page 11
APPENDIX A
XP-250 / 12VDC
13.8 VDC
10.4 / 10.6 VDC
16.5 VDC
24.5 A 27.8 A
XP-250 / 24VDC
27.6 VDC
19 / 21 VDC
33 VDC
12.3 A 14 A
XP-250 / 48VDC
55.2 VDC
41.5 / 42.5 VDC
62 VDC
6.1 A 6.9 A
XP-250 / 66VDC
75.9 VDC
57.5 / 58.5 VDC
91 VDC
4.5 A 5 A
XP-250 / 108VDC
124.0 VDC
94 / 95 VDC
149 VDC
2.7 A 3 A
MODEL
NORMAL
VDC
(TYPICAL)
MINIMUM VDC
CUT-OFF / ALARM
(TYPICAL)
MAXIMUM
VDC
(TYPICAL)
RATED
CURRENT
PEAK
CURRENT
XP-250 / 12VDC
MODEL
Input Power Requirements:
Recommended Input Wire Sizes (For Variable Distances from the Battery):
8 AWG
LESS THAN 5’
4 AWG
LESS THAN 10’
4 AWG
LESS THAN 15’
2 AWG
LESS THAN 20’
XP-250 / 24VDC 12 AWG 10 AWG 8 AWG 6 AWG
XP-250 / 48VDC 18 AWG 16 AWG 14 AWG 14 AWG
XP-250 / 66VDC 18 AWG 18 AWG 16 AWG 16 AWG
XP-250 / 108VDC 18 AWG 18 AWG 18 AWG 18 AWG
Note: The table specifies standard wire sizes (not smaller than 18 AWG) that will provide less than a
2% voltage drop at Low-line Input voltage and Rated Output Power.
XP-250 Mechanical Specifications:
10.768
10.596
10.096
.786”
0
0
.250”
4.977”
5.227”
.218” SLOT 4 PLACES”
0
2.770”
TOP
FRONT
SIDE