Specifications
OUTPUT POWER
INPUT
GENERAL
PROTECTION
CIRCUITRY
ENVIRONMENTAL
MECHANICAL
*indicates typical cut-off voltage/warning buzzer voltage
CONTINUOUS
POWER
SURGE
POWER
(3 seconds)
NO LOAD
POWER
OUTPUT
VOLTAGE
OUTPUT
CURRENT
WEIGHT
LBS.
1000W 2200W 20W 230+/-6% 4.3 7.5
1000W 2200W 20W 117+/-6% 8.6 7.5
MODEL
VOLTAGE
SYSTEM
(TYPICAL)
MINIMUM
(TYPICAL)
MAXIMUM
(TYPICAL)
TYPICAL
EFFICIENCY
@ FULL
POWER
PEAK
EFFICIENCY
@ 1/3
POWER
12V 10.4/10.6* 13.8V 17V 85% 87%
24V 19/21V* 27.6V 34V 87% 89%
32V 26.5/28V* 36.8V 45V 87% 89%
48V 41.5/42.5V* 55.2V 62V 87% 89%
66V 57.5/58.5V* 75.9V 94V 88% 90%
108V 94/95V* 124V 149V 88% 90%
CONDITIONS MINIMUM TYPICAL MAXIMUM
WAVEFORM - SINUSOIDAL -
LINE REGULATION - .1% .5%
LOAD REGULATION - .3% .5%
DISTORTION - 1.5% 2%
FREQUENCY* -.1% NOMINAL +.1%
Over Voltage: Shutoff at maximum input
voltage, per input conditions.
Under Voltage: Shutoff at minimum input
voltage, per input
conditions.
Thermal: 105 C internal
temperature. Warning
buzz 5 C before shutoff.
Output Short: Unit shuts off: Circuit
breaker protected and
electronically limited.
Temperature: -25 to 40 C full power,
derate 20% per 10 C.
Above 40 C.
Humidity: 5 to 95% non-condensing
Altitude: -200 to 10k feet full
power, derated above 10k
Audible Noise: Less than 45dbA
Cooling: 1KW-Thermostatically
controlled forced air
Finish: Polyurethane base paint
Warranty: Full year parts and labor.
Four case sizes are available; all are:
7" high X 15" deep.
19 inch Wide: (includes hardware for
rack or shelf mounting)
23 inch Wide: (includes hardware for
rack or shelf mounting)
9.97 inch Wide: (for 1 to 3KW applications:
surface mounting only)
7 inch Wide: (for 1 or 2KW applications;
surface mounting only)
Available in other sizes including metric. Call
factory for sizes.
1000W
2200W
20W
100+/-6% 10.0
7.5
*50, 60, 400Hz nominal
MX SERIES POWER INVERTER SPECIFICATIONS
See www.exeltech.com for more data regarding MX Series inverters.
Page 8