User manual
10
EXCELL PRECISION CO., LTD.
01008043
ZSME100000091
4-2 F2 ⇒ Transmission Mode ( RS-232 )
Weight kg Unit Price $/kg Total Price $
Press number key 0 , 1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 to choose 0,1,2,3,4,5,6,7,8 in order
0 ⇒ Press M+ and MC key transmit RS232
1 ⇒ Continuous transmission (only RS-232)
2 ⇒ Stable transmission (only RS-232)
3 ⇒ RS-232 off
4 ⇒ Continious transmission (weight transmission only)
5 ⇒ Stable transmission (weight transmission only)
6 ⇒ Continuous transmission (printing format: +001.000)
7 ⇒ Stable transmission (printing format: +001.000)
8 ⇒ Command mode
Press T the next setting mode.
Press M+ to save setting values. The scale will count backwards to zero and
back to weight mode.