Instructions / Assembly
·
19
·
RUNNING THE ENGINE
Ifcannotrestarttheengine,checktheengineoillevelrstbeforego
to other check items.
BREAKER (Electric-start type)
The breaker will cut off automatically to protect the charging circuit of
the battery in the case that short circuit or incorrect connection of the
battery poles occurs.
The green indicator in the breaker will jump out with the circuit cutting
off. After nding troubles and troubleshooting, depress the breaker button
to turn the breaker on.
KIT HIGH ALTITUDE REPLACEMENT FOR EPAIII ENGINES
3000ft to 6000ft or 6000ft to 8000ft of elevation
﹡ At high altitude, the standard carburetor air-fuel mixture will be too
rich. Performance will decrease and fuel consumption will increase. A
very rich mixture will also foul the spark plug and cause hard starting.
Operation at an altitude that differs from that at which this engine was
certied, for extended periods of time, may increase emissions.
﹡ The fuel system on this Engine or Equipment may be influenced
by operation at higher altitudes. Proper operation can be ensured by
installing an altitude kit when required. See the table below to determine
when an altitude kit is required. Operating this generator without the
proper altitude kit installed may increase the engine’s emissions and
decrease fuel economy and performance. Kits may be obtained from any
Dealer, and should be installed by a qualied individual.