User Manual

CODE CHART
TROUBLESHOOTING (Continued)
*Does not apply to XLERATOReco models
**Only applies to HEPA models
If problem cannot be resolved with the above, please call the manufacturer at 1-800-255-9235
and one of our trained technicians will be happy to assist you.
XL1 Cover(includesNameplate)
XL2 Nameplate
XL3 Tamper-ProofBolt
XL4 Tamper-ProofWrench
XL5 AirOutlet(includesgasket)
XL6 TerminalBlock(includesscrews)
XL7 ControlAssembly&Sensor
XL8 HeatingElementAssembly*
XL 9 Motor
XL10 BasePlateAssembly
XL11 CoverMountingBrackets
XL12 HousingGrommet
XL 13 Housing Retainer
XL15 OpticsAssembly(Sensor)
XL16 Fuseholder(ifsoequipped)
XL17 Fuse(ifsoequipped)
XL18 HEPAPre-Filter**
XL19 HEPAFilterAdapter**
XL20 HEPAFilter**
XL21 Pre-Filter
PARTS LIST
Ref. No. Description
XL1
XL
2
(Location)
XL6
XL3
XL4
XL9
XL7
XL11 (2)
XL13 (4)
XL10
XL12(4)
XL8
XL16
XL17
XL18
XL5
XL20
XL19
XL16
XL17
XL7
XL15
XL21
W / HEPA FILTER OPTION
DRYER MAINTENANCE CODES
1SHORT/1LONGFLASH CloggedPre-Filter CleanPre-Filter Dryer will still run
1SHORT/2LONGFLASH SeverelycloggedPre-Filter CleanPre-Filter Dryer will stop
1SHORT/3LONGFLASH No pressure detected
Airsensortubemissingor
control not mounted correctly
Dryer will still run
2SHORT/1LONGFLASH Inlockoutmode Clearobstruction
Dryer stops until obstruction
cleared
MOTOR PROBLEM CODES
1LONG/3SHORTFLASH MotorOverCurrent Replace Motor Dryer will stop
1LONG/4SHORTFLASH MotorUnderCurrent Replace Motor Dryer will stop
HEATER PROBLEM CODES
2LONG/3SHORTFLASH Shorted or incorrect heater Replace Heater Dryer will stop
2LONG/4SHORTFLASH Open/brokenheater Replace Heater Dryer will still run
EXCEL DRYER, INC 1.800.255.9235 EXCELDRYER.COM ADMIN@EXCELDRYER.COM
357 CHESTNUT STREET, EAST LONGMEADOW, MA 01028
12/2015 4
Dryer blows only cold air (non-ECO dryers)
1. Checkheatsettingoncontrol.
2. CheckforlooseconnectionstoHeatingElement.
3. Replace Heating Element.
Dryer has loss of air volume
1. Checkmotorspeedsettingoncontrol.
2. CheckforslowrunningMotororburningsmell.Ifso,replaceMotor.
3. CheckPre-Filterforlintbuildup.CleanbyremovingPre-Filterandrinseinwarm
waterthendryPre-Filterbeforereinstalling.
CodesaredisplayedbytheashingoftheredLEDlightinthesensorbehindairoutlet.
Normal operation will be indicated by the red LED being on when not drying and off when hands are under the sensor.