Specifications

Excalibur Multirate DAP Installation and Operation
4-14
3. Press any front panel button that you wish to verify. The screen displays the
name of the button pressed on the bottom line. If you press buttons 1 - 4, the
Test indicator lights. If you press any other button, the User indicator lights.
1
234
Escape
Top
L
P r e s s < - - a n d - - > t o e n d
L
P r e s s < - - a n d - - > t o e n d
E S C K e y
<
>
4. To return to the Top Level menu, press the < and > buttons simultaneously. (The
display automatically returns to the Top Level menu if no buttons are pressed for
5 seconds.)
1
234
Escape
Top
L
P r e s s < - - a n d - - > t o e n d
<
>
Auto-Learn Network
This feature allows you to make the central unit automatically learn the T7 address of
each remote unit on the multidrop circuit. This option appears on the screen only when
the Service parameter is set to DDSNI, the Location parameter is set to central, the
Network parameter is set to multipoint, and the Automatic Poll parameter is set to
enabled in the DAP Configuration submenu. To activate this function, follow these steps,
starting from the Top Level menu:
1. Press the > button.
1
234
Escape
Top
T
E x c a l i b u r D A P
L o c a l R e m o t A d d r s S e r v e >
<
>