Specifications
Using the Front Panel
4-5
Note: LADC only appears on the screen for units equipped with the Model A or C
Aggregate card.
Entering Unit Addresses
For the Remote Control Panel (RCP) feature to operate properly, you must assign a
unique address to each Excalibur Multirate DAP in the circuit. The address can be any 3-
digit number between 001 and 255.
There are two different addresses that must be entered into each unit:
• Local - the address of the local DAP.
• Remote - the address of the DAP you wish to control when operating in Remote
Mode.
To enter these addresses, follow these steps, starting from the Top Level menu:
Note: In the illustrations that follow, the shading indicates which button to press.
1. Press the button beneath Addrs.
4
Escape
Top
T
E x c a l i b u r D A P
L o c a l R e m o t A d d r s S e r v e >
2. Press the button beneath the address you wish to set. The screen then displays the
current address in the top line with a cursor under the rightmost digit.
4
Escape
Top
D r o p A d d r e s s
L o c a l R e m o t
If you are setting a DAD address, follow Step 3. If you are setting a DAP address, skip to
Step 4.










