Specifications
Installing the DAP
3-15
To make this connection, you must order Cable Part No. 5956-178G from Milgo. One
end of this cable has a 10-pin connector that plugs into the EXT ALM jack. The other
end of this cable must be fitted with a connector appropriate to the alarm device at the
time of installation. Table 3-9 lists the pin/signal assignments for this connector. (The
leftmost pin is designated pin 1.)
Table 3-9. External Alarm Connector, Pin/Signal Assignments
Pin
No. Signal
Input/
Output Function
1 Not Used – –
2 Not Used – –
3 Not Used – –
4 Not Used – –
5 Ground – Signal and supply ground.
6 External Alarm Input Active high external alarm.
7 Not Used – –
8 Not Used – –
9 External Alarm Input Active low external alarm.
10 Not Used – –
DMM Connector
Central site versions of the Excalibur Multirate DAP have an additional connector,
labeled DMM, that is not provided on standalone units. This connector is typically used
in central site applications to daisy-chain the CMS system diagnostic channel. Use Cable
Part No. 5956-849U to connect the DMM connector on the first unit to the NMI
connector on the next unit. Continue to daisy-chain units in the same manner: DMM to
NMI.