Specifications

Excalibur Multirate DAP Installation and Operation
A-2
Operating Range
Line Rate (Kbps) Wire Gauge Distance* (feet) dB
72 19 60k -45
72 26 17k -45
56 19 64k -45
56 26 18k -45
19.2 19 71k -40
19.2 26 25k -40
9.6 19 87k -40
9.6 26 34k -40
4.8 19 114k -40
4.8 26 47k -40
2.4 19 154k -40
2.4 26 66k -40
* Distance meets AT&T Publication 62310 impairment requirements.
Environmental
Ambient Temperature 32
o
F to 122
o
F (0
o
C to 50
o
C)
Relative Humidity 10% to 95% (
+
5%) noncondensing
Storage Temperature -40
o
F to 158
o
F (-40
o
C to 70
o
C)
Power
Standalone Power
Requirements 92-127 VAC, 47-63 Hz
Power Consumption 22 Watts maximum
Power Dissipation 75 BTUs per hour
Aggregate Board MTBF 52,000 hours