To activate this feature from the DAP's front panel, follow these steps:
1. Enter front panel commands to originate a dial backup connection with the
answering DAP. See Chapter 6, "Entering Telephone Numbers" and
"Originating Dial Backup Calls" for instructions.
2. When the dial backup connection has been established, switch back to the
dedicated lines by pressing the button beneath Line in the Call submenu. Then
press the button beneath Ded. The DAP retains the dial backup connection and
returns primary channel data to the digital lines.
Analog Dial Parameters
The Dial submenu contains the parameters which control the operation of the Analog
IDBU feature. Table 5-13 lists these parameters along with their possible settings.
Parameters are listed in the order they appear on the screen. The screen abbreviation for
each parameter is shown in parenthesis.
Table 5-13. Analog Dial Parameters
Parameter Possible Settings
Dial Mode (DMode) 32BIS, BIS+
Speed 14,400, 12,000, 9600
1
, 9000
1
4800,
4500, 2400, 2100
Transmit Clock (TxClk) Internal, External, Slave
Dialer (Dialr) Autosense, Pulse, Tone
Wait to Dial (DWait) 2, 10, 20 seconds, Tone
Call Progress (Prgrs) Enabled, Disabled
Automatic Dial (ADial) DDS Down, No Signal, Network
Down, DTR, None
Automatic Dial Timer (ADTim) 5, 15, 30, 60 seconds
Switch to Dial (SDial) Always, DTR On