Specifications
Excalibur Multirate DAP Installation and Operation
5-24
4. Press the button beneath the channel you wish to set. (To set Channels 4 - 6, you
must first press the > button.) The screen now displays the channel's current DTE
data rate and possible options.
1
2
34
Escape
Top
L
D e f i n e C h a n n e l S p e e d s
A l l C 1 C 2 C 3 >
L
C 1 = 2 4 0 0
5 2 8 0 0 5 1 6 0 0 5 0 4 0 0 4 9 2 0 0 >
<
>
For DAPs with Part No. 15-09Bxx2x0xxx, the possible DTE data rate options
are.
• Synchronous DTEs - 1.2 to 52.8 Kbps in multiples of 1200 bps (except
3.6 and 6 Kbps are not provided) and none.
• Asynchronous DTEs - 75, 150, 300, 600 bps and 1.2, 2.4, 4.8, 7.2, 9.6,
12, 14.4, 16.8, 19.2, 24, 28.8, 48 Kbps, and none.
Notes: Data rates below 1.2 Kbps take up 1.2 Kbps of aggregate data channel
bandwidth.
For proper operation, central and all remote units must have the same channel rate
assignments.
For older DAPs, the possible DTE data rate options are:
• Synchronous DTEs - 1.2, 2.4, 4.8, 7.2, 9.6, 12, 14.4, 16.8, 19.2, 28.8,
38.4, 52.8 Kbps, and none.
• Asynchronous DTEs - 75, 150, 300, 600 bps: 1.2, 2.4, 4.8, 7.2, 9.6, 12,
14.4, 16.8, 19.2 Kbps, and none.
Notes: The 28.8 Kbps port rate is only supported for Excalibur Multiport DAPs
equipped with the Model B Multiport card. For Excalibur Multirate DAPs, channels may
be assigned the 28.8 Kbps port rate for compatibility with multiport units, but an error
message appears on the screen if you try to assign the port to a channel set at this rate.