Installation manual

THE WATER SOFTNER IS NOW READY FOR TESTING
1. With the bypass valve in the bypass position, manually pour
5 gallons of water into the Water Softener brine tank.
2. Press and hold the Water Softener regeneration button for
three seconds until the motor drive starts. Wait until the
motor stops and the display reads “Backwash”. The
backwash time will begin to count down.
3. Open the inlet handle of the bypass valve very slowly
allowing water to fill the Water Softener slowly to expel air. If
water flows too rapidly, there will be a loss of media out of
the drain.
4. When the Water Softener is flowing steadily to drain without
the presence of air, press the Water Softener regeneration
button to advance the Water Softener control valve to the
brine position. The brine time will begin to countdown.
5. Fully open the inlet of the Water Softener bypass valve
(bypass is no in the diagnostic position). Check to verify that
water is being drawn from the brine tank. There should be a
slow flow to the drain. Allow three minutes for the media bed
to settle.
6. Press the Water Softener regeneration button to advance
the Water Softener control valve to where the display reads
fill. This will allow water to run into the brine tank and
prepare it for the next regeneration. Allow the brine to fill
automatically.
7. While the Water Softener brine tank is filling, load two 20kg
bags of water softener salt.