User`s manual
www.exatron.com 5-1 3/19/01
Chapter 5 Manual Mode
This chapter describes all the functions available in Manual Mode. To enter Manual Mode simply press
the
[MANUAL]
key. This key may be pressed at any time. If the handler is cycling parts, pressing the
[MANUAL]
key will pause the handler and immediately enter Manual Mode.
The Display will read:
MANUAL MODE
Following is a complete outline of all the functions in Manual Mode.
The user may press
[Clear]
at anytime to cancel a selection and return to the previous step.
[TOTALS]
key =
DISPLAY TOTALS
.
[1]
Displays totals for tube 1.
T01 0000 000000
[2]
Displays totals for tube 1.
T02 0000 000000
[3]
Displays totals for tube 1.
T03 0000 000000
[4]
Displays totals for tube 1.
T04 0000 000000
[5]
Displays totals for tube 1.
T05 0000 000000
[6]
Displays totals for tube 1.
T06 0000 000000
[7]
Displays totals for tube 1.
T07 0000 000000
[8]
Displays totals for tube 1.
T08 0000 000000
[Enter]
key returns to manual mode.
[1]
key =
T SITE = _ _ _ _ _
This option sets the number of motor steps from the zero point to the test site. The factory default is
46585.
Enter changes to the Test Site step count using the controller keypad number keys. The handler allows
changes to each digit from lowest to highest in order. First enter Ones, then Tens, then Hundreds, etc.
For example:
to enter a step count of 54321
devices, press
[1]
, then
[2]
, then
[3]
, then
[4]
, then
[5]
. The
display will read:
T SITE = 54321
.
Press the
[Clear]
key to erase your entry.
Press the
[Enter]
key to set this number into memory and proceed to the next menu option.
[2]
key =
FULL TUBE = _ _ _ _
This option sets the number of parts for a full output tube. The factory default is 0050.
Enter changes to the Full Tube count using the controller keypad number keys. The handler allows
changes to each digit from lowest to highest in order. First enter Ones, then Tens, then Hundreds, etc.
For example:
to enter a tube count of 4321
devices, press
[1]
, then
[2]
, then
[3]
, then
[4]
.
The display will read:
FULL TUBE = 4321
.
Press the
[Clear]
key to erase your entry.
Press the
[Enter]
key to set this number into memory and proceed to the next menu option.
Tube #
Parts currently in tube.
Total number of parts from this tube
since last clearin
g
of total count in RAM.