User`s manual
Chapter 4 Diagnostics
www.exatron.com 3/19/01
4-2
Diagnostics Quick Reference
↵
↵↵
↵
This symbol means:
Press
the
[Enter]
button
.
[DIAGNOSTICS]
Enters
DIAGNOSTICS
Menu.
[1]
key =
SENSOR CHECK
, then:
[1]
key =
SENSORS 0-8
;, then:
SENSOR NUMBER SENSOR NAME
0 PICKUP HEAD VACUUM
1 INDEX VACUUM A
2 INDEX VACUUM B
3 INDEX VACUUM C
4 INDEX VACUUM D
5 PICKUP HEAD BLOW OFF
6 MOTOR HOME
7 DOOR INTERLOCK
8 PLUNGE SENSOR
[2]
key =
STACK ABCD
sensors.
[3]
key =
TOP
of tube sensors.
Sensors 1-8 correspond to the top of each of the output tube tracks.
[4]
key =
BOTTOM
of tube sensors.
Sensors 1-8 indicate if corresponding tube has parts in the tube.
↵
↵↵
↵
to return to
SENSOR CHECK
.
↵
↵↵
↵
To return to DIAGNOSTICS Menu.
[2]
key =
OUTPUT CHECK
, then:
[1]
key =
SOLENOID CHECK
. The following outputs will cause the
corresponding solenoid to
cycle continuously until the
[Enter]
key is pressed.
[1]
Solenoid #1 Index Vac A
[2]
Solenoid #2 Index Vac B
[3]
Solenoid #3 Index Vac C
[4]
Solenoid #4 Index Vac D
[5]
Solenoid #5 Index Pin A
[6]
Solenoid #6 Index Pin B
[7]
Solenoid #7 Index Pin C
[8]
Solenoid #8 Index Pin D
[9]
All Solenoids ON
[0]
All Solenoids OFF
↵
To return to OUTPUT CHECK Menu.