User`s manual

Chapter 2 Handler Setup
www.exatron.com 3/19/01
2-8
00A6 Check Sort Reset FF 00, FF Enable the handler to check whether all sort signals are OFF at
the start of the test. To enable this option, set this address to 00.
To disable this option, set this address to FF. Set this to FF
especially when using LED checker boxes for simulation
purposes.
00A7 Reserve A7 Not Used At This Time.
00A8 Reserve A8 Not Used At This Time.
00A9 Reserve A9 Not Used At This Time.
00AA Stop on Fail Y/N 30 30, FF
See
Display
Diction-
ary
for
further
details.
Set to 30: Upon receipt of a fail signal from the tester, the handler
will place the device into the pre-assigned fail tube.
Set to FF: After the handler receives a fail signal from the tester,
the handler will stop with the contacts closed. This will allow the
operator to inspect contact alignment or increase/de- crease
contact pressure.
00AB Reserve AB Not Used At This Time.
00AC Reserve AC Not Used At This Time.
00AD D Test ASCII Out D See
Interface
Chapter
for
further
details.
This is the ASCII letter which the E
XATRON
RS-232 interface uses
as an output on a double test.
Set to S: Normal. Set to D: Handler will issue S on First Test
Cycle and D on Double Test Cycle.
00AE Reserve AE Not Used At This Time.
00AF Reserve AF Not Used At This Time.
00B0 Reserve B0 Not Used At This Time.
00B1 Reserve B1 Not Used At This Time.
00B2 Reserve B2 Not Used At This Time.
00B3 Reserve B3 Not Used At This Time.
00B4 Reserve B4 Not Used At This Time.
00B5 Reserve B5 Not Used At This Time.
00B6 Reserve B6 Not Used At This Time.
00B7 Reserve B7 Not Used At This Time.
00B8 Reserve B8 Not Used At This Time.
00B9 Reserve B9 Not Used At This Time.
00BA Reserve BA Not Used At This Time.
00BB Stop-Fail Sort 00 00 to FF Tells the handler which test sorts to stop operation on Fail signal
if desired. 00 = Stop on Fail feature is OFF for all sorts. FF =
Stops on Fail for ALL devices. FE = Sort 1 is PASS and all other
sorts are Stopped upon Fail.
00BC Double Test Sort 00 00 to FF Tells the handler which test sorts to double test if desired. 00 =
Double Test OFF for all sorts.
FF = Double Tests ALL devices. FE = Sort 1 is PASS and all
other sorts are Double Tested.
00BD Send H on Retest FF 00, FF When this option is set to 00, the system will send an “H” signal
(initiating communication) to the tester at the start of a second
test of a device. When set to FF, the system will not send an “H”
before a second test cycle.
00BE Reserve BE Not Used At This Time.
00BF Reserve BF Not Used At This Time.
00C0 Sort 1 Bins 1-8 7F 00 to FF Input Sort 1 to handler output bins. BIT MAP.
Output cover LEDs will blink output sort locations.
00C1 Sort 2 Bins 1-8 80 00 to FF Input Sort 2 to handler output bins. BIT MAP.
Output cover LEDs will blink output sort locations.
00C2 Sort 3 Bins 1-8 80 00 to FF Input Sort 2 to handler output bins. BIT MAP.
Output cover LEDs will blink output sort locations.
00C3 Sort 4 Bins 1-8 80 00 to FF Input Sort 2 to handler output bins. BIT MAP.
Output cover LEDs will blink output sort locations.