Chapter 2 Handler Setup
www.exatron.com 3/19/01
2-7
The following table describes each firmware address in numerical order. This information is
current as of the date of this manual. A system-specific RAM setting printout should appear at the
end of this chapter which will have the RAM settings as they were saved in the EPROM on this
system when it shipped from Exatron. As a result, some of the settings shown below may not
+agree with those on your system. Use the listing at the end of this chapter for settings specific
to your handler.
TABLE 1 Handler RAM
Adrs Description ROM RAM Op Comments
008F Type6-2 02-14-01 1 N/A Sign on message. Not to be modified by user.
0090 Handler Type 00 00 TYPE 6 Handler
0091 Head Up Sensor
Option
00 00, FF FF= No sensor, 00 = Head up sensor present.
0092 Full Tube 1000s 30 30 to 39 Set the 1000s digit for number of devices constituting a full tube
(ASCII)
0093 Full Tube 100s 30 30 to 39 Set the 100s digit for number of devices constituting a full tube
(ASCII)
0094 Full Tube 10s 35 30 to 39 Set the 10s digit for number of devices constituting a full tube
(ASCII)
0095 Full Tube 1s 30 30 to 39 Set the 1s digit for number of devices constituting a full tube
(ASCII)
0096 Precisor On/Off FF 00, FF Index Precisor. On = 00, Off = FF
0097 Start Test Delay 10 00 to FF Time delay for test site solenoids to close. Counts down in HEX
to determine the time delay in milliseconds.
0098 Start Pulse Width 14 00 to FF Adjust the start test pulse width. This is allowed to provide
flexibility in interfacing between the handler and
tester/programmers. Counts down in HEX in 1 millisecond steps.
0099 Remote Go FF 00, FF For E
XATRON
S
UPER
Interface only.
To run the system using the PC as the controller and E
XATRON
-
supplied system software, set this address to 00. To run the
system
without
using the PC as the controller, set this address
to FF.
009A Count Mask 00 00, 10 Allows the operator to designate a bin or bins that will ignore the
pre-defined full tube count. This is useful when using bulk/bucket
outputs.
For example, bit map 10 = Sort 5.
009B Baud Rate RS-232 0C See
Table in
Interface
Chapter
Stores the baud rate of the RS-232 interface between the handler
system and the PC.
Must be set to 0C for E
XATRON
S
UPER
Interface.
009C Data Format 07 See
Table in
Interface
Chapter
Stores the parity/stop/data bits.
Must be set to 03 for E
XATRON
S
UPER
Interface.
009D ½ “ or 1” Pitch 00 00, FF 00 = 1” Pitch, FF = ½” Pitch.
009E Time Out 20 00, FF A timed delay before the handler aborts the test and turns off all
solenoids. Counts down in HEX in 1 second steps. When this
address is set to 00, the system will never time out.
009F Test Site Steps
10,000’s
4 (ASCII) Set the 10,000’s digit for number of motor steps from zero point
to test site. (ASCII)
00A0 Test Site Steps
1,000’s
6 (ASCII) Set the 1,000’s digit for number of motor steps from zero point to
test site. (ASCII)
00A1 Test Site Steps
100’s
6 (ASCII) Set the 100’s digit for number of motor steps from zero point to
test site. (ASCII)
00A2 Test Site Steps
10’s
1 (ASCII) Set the 10’s digit for number of motor steps from zero point to
test site. (ASCII)
00A3 Test Site Steps
1’s
5 (ASCII) Set the 1’s digit for number of motor steps from zero point to test
site. (ASCII)
00A4 Reserve A4 Not Used At This Time.
00A5 Reserve A5 Not Used At This Time.