User`s manual

Chapter 2 Handler Setup
www.exatron.com 3/19/01
2-3
METHOD 2
To enter the setup menu from power up, do the following.
Turn the handler on. Do not load any parts into the system.
The display will do a self test and sign on.
V0 2.00 Test Ok
TYPE 6-2 02-14-01
The motor will then home.
HOME PICKUP
SERVO IS AT 0
The handler will then check that the index pickup sites are clear. If parts are present they will be picked
and transferred to the flush bin.
The display will then read:
MOD SETUP NO ?
The
[SETUP]
key will toggle between
MOD SETUP NO ?
and
MOD SETUP YS ?
Press the
[SETUP]
key to change the display to
MOD SETUP YS ?
Press the
[Enter]
to start Modification Setup. Display will read
T SITE = _ _ _ _ _
If the
[Enter]
or
[SETUP]
key is not pressed, the microterminal will “time out” in five seconds and proceed
to run mode. The display will read
READY TO RUN
.
Continue with the section entitled
MOD SETUP YS ?
to complete setup.