User's Manual

Table Of Contents
Exalt Installation and Management Guide
ExtendAir G2 24GHz Digital Microwave Radios
64 209866-002
2015-09-09
indicated by T=(value). This is followed by the value of the measurement, listing the highest value,
lowest value and average value measured over that time interval.
For example, if the displayed time interval is minutes, and the cursor is held at the T=17 mark on the
horizontal axis, the measurements shown indicate performance from 17 minutes ago. The high/low/
average values shown on each chart are measurements made across that specific one-minute interval.
The Far-End Transmit Power chart displays when any combination of ATPC or Receiver Overload
Protection is enabled (see ATPC Configuration Page
). This chart shows the far-end transmitter
changes that are occurring relative to the provided RSL information. Since the far-end transmit power
can change on links using ATPC or Receiver Overload Protection, this information is very useful for
troubleshooting.
Changes in RSL often have an impact on BER, and this can be confirmed by looking for synchronized
events. When BER events occur without corresponding changes in RSL, this normally indicates
interference, atmospheric changes, transmission system issues (such as problems with cables,
connectors, or antennas), or possibly radio hardware problems.