User's Manual

Table Of Contents
Exalt Installation and Management Guide
ExtendAir
®
(TDD) Series Direct Mount
74 000000-001
2011-08-26
Specifications
This section presents specifications for the ExtendAir digital microwave radios.
Physical Specifications
Common System Specifications
Physical Configuration Outdoor Unit (ODU)
Dimensions (HxWxD) 9.4 x 9.4 x 5.25 inches / 23.9 x 23.9 x 13.34 cm
Weight 8.2 lbs/3.6 kg
Operating Temperature –40 to +149°F /–40 to +65°C
Altitude 15,000'/4.6 km
Humidity 100% condensing
Environmental NEMA4/IP66
Power Control Step Size 0.5dB
Selectable Modulation Modes QPSK, 16QAM, 64QAM
Maximum RSL 0dBm no damage
QPSK: –25dBm error-free
16QAM & 64QAM: –30dBm error-free
Aggregate User Capacity (Mbps) Max system
layer 1/Max Ethernet layer 2
a
b
a. Capacity over 200Mbps aggregate can be achieved for radios that have TDM interfaces in addition to 100BaseT
Ethernet.
b. Maximum layer 1 throughput as measured with 64-byte packets and maximum layer 2 Ethernet + TDM
throughput as measured with 1536-byte packets. In both cases throughput includes source address, destination
address and CRC overhead.
Ethernet Latency <250μs typical
Error Floor
10
-12
Link Security 96-bit Security Code, optional NIST FIPS-197
compliant 128-bit or 256-bit AES encryption.
QPSK 16QAM 64QAM
16MHz 31/27 64/55 96/81
32MHz 64/55 129/110 187/163
64MHz 129/110 200/197 200/197