User's Manual

Table Of Contents
Exalt Installation and Management Guide
ExtendAir
®
(TDD) Series Direct Mount
10 000000-001
2011-08-26
Radio Reset
Use the reset function if the IP address and/or passwords are lost. Use the following steps to perform a
critical parameter reset:
1 Remove power from the radio by disconnecting the AC adapter from the power injector.
2 Hold down RESET button on the power injector while applying power.
Hold the RESET button down through the entire power cycle and monitor the DATA+POWER
left LED on the power injector. Release the RESET button only after the LED is in the steady state
(45 to 60 seconds).
3 Release the RESET button.
The following configurations are reset on the radio:
IP address = 10.0.0.1
IP mask = 255.0.0.0
IP gateway = 0.0.0.0
Administration password = password
Table 1 Factory default settings
Parameter ExtendAir
®
(TDD) Series Direct Mount Radio Settings
Link Distance <10 miles
Bandwidth 16 MHz
Mode Mode 1
TDD Frame Size 2ms
Link Security Key 000000000000
Administration Password password
User Password password
IP Address 10.0.0.1
IP Mask 255.0.0.0
IP Gateway 0.0.0.0
Ethernet Interface Alarm Enabled, 100/Full
T1/E1 Enabling All Disabled
Note: In many cases, the system design will not be identical to the factory default
configuration, and in some cases, these differences prohibit the installation of the radio. If at
all possible, obtain a computer and configure the radio terminals using the browser-based
GUI. See Exalt Graphical User Interface (GUI)
for details.