User's Manual

Table Of Contents
Exalt Installation and Management Guide
ExtendAir (TDD) Series Digital Microwave Radios
84 203591-010
2012-09-04
The watermark level function allows administrators to receive an SNMP trap when watermark
conditions are exceeded. For example, if a radio is configured for 55 Mbps capacity, the administrator
may wish to be warned if the radio exceeds 50 Mbps for more than 1 hour per day. In this case, set the
watermark level to 50% and the trap duration to 60 minutes. Traps must be enabled for this function to
be active.
When the watermark level function is enabled, a line on the chart appears for data comparison to the
watermark.