RF
TDM (TDM models only)
Ethernet (1 interface on xx00 models, 3 interfaces on xx05 models)
Sync-In Sync-Out
Power — DC Power Injector (sold separately)
Power — AC adapter/injector (sold separately)
Integrated Antenna (r models only)
Connector N-type female
Impedance 50 Ohms
Connector RJ-45 (RJ48C), female
T1 Impedance 100 Ohms, balanced
T1 Line Codes AMI, B8ZS, selectable
T1 LBO Settings (in ft.) 0–133, 133–266, 266–399, 399–533, 533–655
T1 Clocking Speed 1.544 Mbps
T1 Compliance ANSI T1.102-1987; ITU-T; G.823; GR-49T-CORE
E1 Impedance 120 Ohms, balanced
E1 Line Codes HDB3
E1 Clocking Speed 2.048 Mbps
E1 Compliance CEPT-1; G.703; ITU-T-G703
Connectors RJ-45, female, auto-MDIX
Interface Speed 10 or 100 Mbps
Duplex Half, full, auto, selectable
Compliance 802.3
Connector RJ-45, female
Signal 1pps (GPS or Internal Sync signal)
Connector 6-pin barrier strip
Input Voltage 48VDC
Consumption <25 W (0.6A)
Input 100–240VAC, 0.5A
Output 40W, 56VDC
Gain
(midband) 23dBi