User's Manual

Exalt Communications, Inc.
EX-5r Installation & Management
5000007 12
2006-05-17
2.5.1 Default Settings
It is advised to use the browser-based GUI, or alternatively, the Telnet CLI, to configure the
radio terminals for Radio A and Radio B orientation. Since many other parameters also need to
be set, and the GUI is needed for these configurations, this is the best way to completely
configure the radio terminals.
If the radios are new from the factory or Exalt’s authorized distributor, they will be set to the
factory default configuration. In this case, both radios will be configured as Radio B. They will
also be configured to the factory default settings for:
Frequency = 5780 MHz
Transmit Power = 4dBm
Link Distance = <10 miles
Bandwidth = 8MHz
Mode = Mode 1
TDD Frame Size = 2ms
Link Security Key = 000000000000
Administration Password = admin
User Password = user
IP address = 10.0.0.1
IP mask = 255.0.0.0
IP gateway = 0.0.0.0
Ethernet Interfaces = Enabled; 100/Full
AUX port NMS Access = in-band
T1/E1 enabling = all circuits disabled
DS3 enabling = all circuits disabled
If the current IP address of the radio is unknown, it may be necessary to “reset” some of the radio
parameters to gain management access. A reset connector is provided in the accessory kit for this
purpose.
To use the reset connector, follow these steps:
1. Remove power from the radio by disconnecting power from the power injector
2. Remove the data connector from the power injector (this is the connector normally
connected to your local networking equipment NOT the connector leading up to the
radio)
3. Connect the reset connector to the data port on the power injector
4. Apply power to the power injector
5. Wait 1 minute
6. Remove the reset connector
7. Replace the original data connector to the data port on the power injector
The following configurations are changed on the radio: