User's Manual
Exalt Communications, Inc.
EX-5r Installation & Management
5000007 12
2006-05-17
2.5.1 Default Settings
It is advised to use the browser-based GUI, or alternatively, the Telnet CLI, to configure the
radio terminals for Radio A and Radio B orientation. Since many other parameters also need to
be set, and the GUI is needed for these configurations, this is the best way to completely
configure the radio terminals.
If the radios are new from the factory or Exalt’s authorized distributor, they will be set to the
factory default configuration. In this case, both radios will be configured as Radio B. They will
also be configured to the factory default settings for:
• Frequency = 5780 MHz
• Transmit Power = 4dBm
• Link Distance = <10 miles
• Bandwidth = 8MHz
• Mode = Mode 1
• TDD Frame Size = 2ms
• Link Security Key = 000000000000
• Administration Password = admin
• User Password = user
• IP address = 10.0.0.1
• IP mask = 255.0.0.0
• IP gateway = 0.0.0.0
• Ethernet Interfaces = Enabled; 100/Full
• AUX port NMS Access = in-band
• T1/E1 enabling = all circuits disabled
• DS3 enabling = all circuits disabled
If the current IP address of the radio is unknown, it may be necessary to “reset” some of the radio
parameters to gain management access. A reset connector is provided in the accessory kit for this
purpose.
To use the reset connector, follow these steps:
1. Remove power from the radio by disconnecting power from the power injector
2. Remove the data connector from the power injector (this is the connector normally
connected to your local networking equipment NOT the connector leading up to the
radio)
3. Connect the reset connector to the data port on the power injector
4. Apply power to the power injector
5. Wait 1 minute
6. Remove the reset connector
7. Replace the original data connector to the data port on the power injector
The following configurations are changed on the radio: