User's Manual
Table Of Contents
- EX-i Series GigE (FDD)
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Command Line Interface (CLI)
- Telnet into the Command Line Interface (CLI)
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- NTP and Time Zone Configurations
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- System Configuration Page
- Allocation Page
- Ethernet Interface Configuration Page
- T1/E1 Configuration Pages
- MHS Configuration Page
- VLAN Configuration Page
- Ethernet Rate Limiting Page
- Ethernet Learning Page
- Syslog Configuration Page
- Ethernet Aggregation
- Cross Connect (X Connect) Page
- Alarms Page
- MHS Status Page
- Performance Page
- ATPC Statistics Page
- Event Log Page
- User Throughput Page
- Diagnostic Charts Page
- Ethernet Utilization Page
- PA Control Page
- Spectrum Analyzer
- Reboot Page
- Manual Page
- Specifications
- Interface Connections
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- EIRP Limits for the United States and Canada
- Licensing 6 and 11GHz Models
- Antennas 5GHz Models
- Copyright Notices
- END USER AGREEMENT
- Index
Exalt Installation and Management Guide
EX-i Series GigE (FDD) Digital Microwave Radios
202675-008 47
2016-06-01
System Configuration Page
This page contains several critical system parameters.
Figure 30 System Configuration page
Most entries on this page are self-explanatory. The following lists unique or important parameters.
• Set the Diplexer/Filter Configuration parameter by selecting the diplexer mounted on the rear
panel that matches the label shown right-side-up on the diplexer. Select OTHER if using a custom
diplexer assembly or a diplexer not in the list. If using OTHER, an independent Tx/Rx frequency
input is required.
On some models, when OTHER is selected an additional field is provided to program the insertion
loss of the diplexer. This parameter can be found with the paperwork supplied with the original
diplexer packaging.
• Set the Radio Transmit Power (dBm) parameter to the desired level. The professional installer sets
this value or dictates the value of this setting to the system administrator following the system