User's Manual

Table Of Contents
Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
45 201872-003
2015-10-23
File Transfer Page
This page allows the administrator to upload and download files to and from the radio. Three types of
files can be uploaded: configuration, radio firmware, and Regulatory Domain Database (RDD).
When
uploading Configuration Files, current configuration parameters are immediately
overwritten, and the unit automatically reboots. When uploading radio firmware files, the file
is placed into reserve memory space. After the new radio firmware file uploads, use the File Activation
page to enable the files (see File Activation Page
).
Figure 25 File Transfer page
Up to four types of files can be downloaded: configuration, radio firmware, radio event log, and MIB.
The MIB file refers to the Management Information Base related to the Simple Network Management
Protocol (SNMP) function, and is only available on models which support SNMP. See Simple
Network Management Protocol (SNMP) for more information.
Use the following steps to download a file.
1 Select the type of file to download (configuration or radio firmware).
2 Click the Download button and wait for the radio to prepare the file for download.
Note: Issues with the RDK may be caused when the Regulatory Domain Database (RDD) is
not up to date. Go to the Exalt Web site to download the current RDD
.
Note: Check the existing loaded files before uploading new radio firmware files. New file
uploads overwrite the secondary file location. If important files reside in the primary or
secondary file location, download them before uploading the new files. Only the active radio
firmware file can be downloaded. Therefore, to download the reserve file, it must first be
activated (using the Swap button). See File Activation Page
. The current radio firmware and
RDD versions can be viewed on the Radio Information Page
.