User's Manual
Table Of Contents
- EX-r Series GigE
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the EX-r Series GigE Radios
- Initial Configuration and Back-to-Back Bench Test
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio A/B Configuration
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Telnet into the Command Line Interface (CLI)
- Telnet
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- System Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- GPS Information Page
- Alarms Page
- Performance Page
- Event Log Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Reboot Page
- Manual Page
- Specifications
- 201872-003Interface Connections
- Antennas
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for Australia
- EIRP Limits for the European Union and ITU Countries
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- Copyright Notices
- END USER AGREEMENT
- Index
Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
25 201872-003
2015-10-23
• IP mask = 255.0.0.0
• IP gateway = 0.0.0.0
• Administration password = password
• User password = password
Power
The radio requires a DC power source within specifications. DC can be provided from a DC battery
source, central lab/rack supply, or from the supplied AC adapter.
Terminating the RF Connectors (EX-4.5r-c GigE and EX-5r-c GigE)
Before applying power, the RF connectors must be properly terminated into a 50-Ohm load. If this is
not performed, the radio may be damaged by simply applying power. Also, there are human safety
factors to consider regarding potentially harmful RF radiation.
The following lists a few simple ways to achieve proper termination:
• Connect a 50-Ohm coaxial termination device to the RF port of the radio. The termination must be
rated to 1W (or more). Example(s) include:
– Broadwave Technologies P/N 552-200-002, or similar
• Connect the complete transmission system. That is, the RF cabling including the antenna. The
cabled antenna provides a proper termination for the RF output.
• Connect a fixed (or a series of fixed) 50-Ohm attenuator(s) to the RF connector, either directly or
at the end of an RF transmission line. The attenuator must be at least 30dB as specified at the
operating frequency (~5700 MHz) and rated for a minimum of 1W input power. Examples
include:
– Broadwave Technologies P/N 352-103-xxx
– Bird 2-A-MFN-xx
– JFW Industries 50FP-xxx-H6-N
Cover any unused connector with the connector cap and apply the weather-seal tape. Both cap and tape
are included in the accessory kit.
AC Power
The AC adapter easily connects to the power injector. Refer to the input voltage requirements stated on
the label affixed to the adapter to ensure that the adapter can be used with the AC mains supply.
The AC plug outlet provided with the adapter may need to be replaced to match the country
configuration. The adapter cable uses a standard connector for this cable for use of a pre-wired cable
appropriate to the outlet configuration. If the appropriate cable is not available, the existing AC plug
end can be severed and a replacement plug affixed. Consult a qualified electrician for this activity.
Do not plug the adapter into the mains power. First, verify that the RF connector is properly terminated
(see Power
), and then plug in the radio-side connector from the AC adapter to the radio. If the AC
mains can be turned off using a switch, disable the power, plug the AC side of the adapter into the AC
Note: Read this section completely before applying power.