User's Manual
Table Of Contents
- EX-r Series GigE
- Digital Microwave Radios
- Installation and Management Guide
- Legal Notice
- Open-Source License Information
- Table of Contents
- List of Figures
- List of Tables
- About this Document
- Introduction
- Pre-installation Tasks
- Link Engineering and Site Planning
- Familiarization with the EX-r Series GigE Radios
- Initial Configuration and Back-to-Back Bench Test
- Time Division Duplex (TDD) Factors
- Link Orientation and Synchronization
- Radio A/B Configuration
- Radio Synchronization
- Offset Timing
- Virtual Local Area Network (VLAN)
- Simple Network Management Protocol (SNMP)
- System Installation and Initiation Process
- Installation
- Configuration and Management
- Telnet into the Command Line Interface (CLI)
- Telnet
- Exalt Graphical User Interface (GUI)
- Quick Start
- Navigating the GUI
- Radio Information Page
- Administration Settings Page
- Simple Network Management Protocol (SNMP) Configuration
- File Transfer Page
- File Activation Page
- System Configuration Page
- Ethernet Interface Configuration Page
- VLAN Configuration Page
- T1/E1 Configuration Pages
- GPS Information Page
- Alarms Page
- Performance Page
- Event Log Page
- Diagnostic Charts Page
- Spectrum Analyzer Page
- Reboot Page
- Manual Page
- Specifications
- 201872-003Interface Connections
- Antennas
- Troubleshooting
- Back-to-back Bench Testing
- General Compliance and Safety
- Dynamic Frequency Selection
- Safety Notices
- Regulatory Notices
- Regulatory Compliance
- Regulatory Domain Keys
- EIRP Limits for the United States and Canada
- EIRP Limits for Australia
- EIRP Limits for the European Union and ITU Countries
- Declaration of Conformity to the R&TTE Directive 1999/5/EC
- Copyright Notices
- END USER AGREEMENT
- Index
Exalt Installation and Management Guide
EX-r Series GigE Digital Microwave Radios
201872-003 8
2015-10-23
The radio terminal boxes contain a single pre-terminated PoE cable intended for bench testing and to
make the short connection between the radio and the PoE lightning arrestor near the radio. If running a
longer cable from the radio to the PoE lightning protector (such as at the egress point), use pre-
terminated cables (sold separately). Pre-terminated cables are available in different lengths to meet a
variety of applications, and can also be used for the T1/E1 connections (where applicable).
Initial Configuration and Back-to-Back Bench Test
Every Exalt digital microwave radio goes through extensive quality testing and performance
evaluation over the full operating temperature range prior to shipment. However, before installation, it
is strongly advised to perform several tests and tasks that are much more difficult to perform once the
radio link endpoints are distant from one another. A back-to-back bench test and pre-configuration will
provide confidence that the radio link is operational and properly configured prior to installation, so
that if troubleshooting is necessary, the radio hardware and configuration settings are eliminated from
the troubleshooting process. Verify the following in the back-to-back testing:
• Confirm that the radio system is generally operational
– Radios power-up with planned power and wiring solutions
– Regulatory Domain Key (RDK) entry successful
– RF link connects in both directions
– Traffic passes across the link
– Configure connected equipment and cabling
– Test Ethernet (CAT5e or CAT6) cabling, and/or T1/E1 cabling, any auxiliary connector
cabling and configure all interfaces
– Configure IP settings for configuration and management
– Configure passwords and security modes
– Become familiar with the configuration and management interfaces through the Exalt GUI
interface
– Configure radio parameters
– Set transmitter output power to engineered or allowed level (see RF Output Power Setting
)
– Set operating center frequency
– Set link distance, occupied channel bandwidth, and frame length
• Make detailed radio performance measurements
Note: Exalt radios with the RDK function are DISABLED when initially shipped. To
ENABLE the radio, a valid RDK must be entered on the Administration Settings Page
page of
the Exalt GUI. The RDK references the unit's serial number and is provided based on the
country and/or region where the radio system will be deployed. The RDK is obtained through
your Exalt Authorized distributor or reseller.
Note: Some countries require Dynamic Frequency Selection (DFS), which delays the
transmitter turn-on time during the initial Channel Availability Check period of 1 minute. In
accordance with these regulations, the radios boot up, and then wait for 1 minute before
linking.